Choose Wallbox Pulsar Plus if two cars need to share a charging allowance, or if one charger needs household load management or surplus-solar charging with an extra meter. Choose ChargePoint Home Flex for one charging point when you value managing home and public charging in the same app. Match the connector and installation first: a plug-in Home Flex does not deliver its advertised hardwired maximum. Wallbox features, ChargePoint configurations.

This is a US comparison based on official documents checked November 2, 2026. We have not physically evaluated the chargers.

Quick picks: buy the complete setup

Compare specifications and all conditions

J1772 car and an electrician-approved NEMA 14-50 outlet

Our pick
Pulsar Plus 40A, PUP2
What makes it fit
Matching plug; an option for a compatible sharing installation

New J1772 installation needing Wallbox energy features

Our pick
Pulsar Plus 48A hardwired, PUP2
What makes it fit
Higher output ceiling; add the meter for household sensing or solar

One charger; home and public charging in one app matters most

Our pick
Home Flex with your car's connector
What makes it fit
Choose J1772 or NACS, then the supply connection

Single Wallbox charger needing household sensing or solar

Our pick
Wallbox US Power Meter kit
What makes it fit
Additional equipment, not a substitute for the charger
Full comparison table

Swipe to compare. Row labels stay visible.

Your situationOur pickWhat makes it fit
J1772 car and an electrician-approved NEMA 14-50 outletPulsar Plus 40A, PUP2Matching plug; an option for a compatible sharing installation
New J1772 installation needing Wallbox energy featuresPulsar Plus 48A hardwired, PUP2Higher output ceiling; add the meter for household sensing or solar
One charger; home and public charging in one app matters mostHome Flex with your car's connectorChoose J1772 or NACS, then the supply connection
Single Wallbox charger needing household sensing or solarWallbox US Power Meter kitAdditional equipment, not a substitute for the charger
Your situationOur pickWhat makes it fit
J1772 car and an electrician-approved NEMA 14-50 outletPulsar Plus 40A, PUP2Matching plug; an option for a compatible sharing installation
New J1772 installation needing Wallbox energy featuresPulsar Plus 48A hardwired, PUP2Higher output ceiling; add the meter for household sensing or solar
One charger; home and public charging in one app matters mostHome Flex with your car's connectorChoose J1772 or NACS, then the supply connection
Single Wallbox charger needing household sensing or solarWallbox US Power Meter kitAdditional equipment, not a substitute for the charger

For a wider shortlist, see our best Level 2 home chargers.

Compare equal installations before comparing maximums

Both families offer J1772 and NACS vehicle connectors. NEMA 14-50 describes the supply plug, not the vehicle connector; Wallbox's 48A version is hardwired. ChargePoint also offers a NEMA 6-50 supply version.

NEMA 14-50, configured for 40A output

Wallbox Pulsar Plus
9.6 kW at 240V
ChargePoint Home Flex
9.6 kW at 240V

Hardwired, configured for 48A output

Wallbox Pulsar Plus
11.5 kW
ChargePoint Home Flex
Approximately 11.5 kW at 240V

Family maximum

Wallbox Pulsar Plus
48A; 11.5 kW
ChargePoint Home Flex
50A; 12 kW, hardwired only

Vehicle cable

Wallbox Pulsar Plus
25 ft
ChargePoint Home Flex
23 ft

Safety certification stated by maker

Wallbox Pulsar Plus
UL certification: UL 2594 / UL 2231
ChargePoint Home Flex
UL/cUL listed: UL 2594 / UL 2231-1 / UL 2231-2

Chargers sharing a common circuit

Wallbox Pulsar Plus
Documented Power Sharing, with prerequisites
ChargePoint Home Flex
Maker requires a dedicated circuit per charger
Full comparison table

Swipe to compare. Row labels stay visible.

Compare thisWallbox Pulsar PlusChargePoint Home Flex
NEMA 14-50, configured for 40A output9.6 kW at 240V9.6 kW at 240V
Hardwired, configured for 48A output11.5 kWApproximately 11.5 kW at 240V
Family maximum48A; 11.5 kW50A; 12 kW, hardwired only
Vehicle cable25 ft23 ft
Safety certification stated by makerUL certification: UL 2594 / UL 2231UL/cUL listed: UL 2594 / UL 2231-1 / UL 2231-2
Chargers sharing a common circuitDocumented Power Sharing, with prerequisitesMaker requires a dedicated circuit per charger
Compare thisWallbox Pulsar PlusChargePoint Home Flex
NEMA 14-50, configured for 40A output9.6 kW at 240V9.6 kW at 240V
Hardwired, configured for 48A output11.5 kWApproximately 11.5 kW at 240V
Family maximum48A; 11.5 kW50A; 12 kW, hardwired only
Vehicle cable25 ft23 ft
Safety certification stated by makerUL certification: UL 2594 / UL 2231UL/cUL listed: UL 2594 / UL 2231-1 / UL 2231-2
Chargers sharing a common circuitDocumented Power Sharing, with prerequisitesMaker requires a dedicated circuit per charger

Sources: Wallbox datasheet, CPH50 datasheet, ChargePoint installation FAQ. The matched Home Flex figure is calculated from 240V and 48A, rounded to 11.5 kW.

ChargePoint's manual maps a 60A circuit to 48A charging; its 50A setting needs a different approved hardwired configuration. Have the electrician match the circuit, panel capacity and vehicle requirements before valuing the higher maximum. Installation manual, installation FAQ.

  • 25 ftPulsar Plus vehicle cable
  • 23 ftHome Flex vehicle cable

Outlet pick: Wallbox Pulsar Plus 40A J1772, PUP2

The exact US shop code is PUP2-U-1-5-N-002: J1772, 40A, NEMA 14-50. Its maximum is 9.6 kW, and the charger body is 7.8 × 7.9 × 3.9 inches without its cable. Choose it when the approved outlet fits your installation and Wallbox's sharing capability matters. Official configuration.

Power Sharing still needs communication cabling and professional setup, even for plug-in chargers. A meter is unnecessary for that static sharing feature, but is required for the single-charger household-sensing feature described below. Sharing requirements, household sensing.

See the Wallbox J1772 configurations.

New-installation pick: Wallbox Pulsar Plus 48A J1772, PUP2

Choose PUP2-U-1-6-C-002 for the hardwired J1772 configuration, rated up to 48A and 11.5 kW. It suits a new installation where you want Wallbox energy features and the electrician confirms the available capacity. A licensed electrician must handle hardwiring, with a permit where required. Exact configuration, installation manual, permit guidance.

For a NACS vehicle, Wallbox's corresponding 48A hardwired code is PUP2-U-T-6-C-002. Confirm the actual part number before ordering a second charger; the words “Pulsar Plus” alone do not establish sharing compatibility. The shop data showed the selected 40A J1772 configuration and the 48A NACS alternative unavailable when checked; verify stock before booking installation. NACS configurations, compatibility warning.

See the Wallbox hardwired J1772 configuration.

App pick: ChargePoint Home Flex

Home Flex is our choice when one charging point and a combined home/public app meet the need. Its app supports utility-based schedules, weekday/weekend timing and session information. Choose the connector that matches your car, then decide whether the installation calls for a supply plug or hardwiring. ChargePoint app overview, scheduling features.

Our Home Flex variant guide has the detailed ordering grid. ChargePoint requires a dedicated circuit per charger; staggered schedules do not meet its documented requirements for sharing one circuit. Installation FAQ.

See Home Flex connector and installation options.

Sharing, household load management and solar need different equipment

Static Load Management, called Power Sharing in Wallbox's installation manual, distributes a configured charging allowance between chargers. When insufficient power is available, vehicles can queue. That allowance does not grow when you add another charger. Single-charger Dynamic Load Management, formerly Power Boost, instead measures household demand and adjusts charging to the remaining capacity. Sharing manual, household load management.

Static sharing between Pulsar Plus chargers

Equipment to include in the electrician's quote
Compatible chargers, charger-to-charger communication cable and conduit; no household meter required
Limit to confirm
Shared allowance and local approval for the proposed circuit arrangement

One charger responding to household demand

Equipment to include in the electrician's quote
Charger, Wallbox-approved meter and clamps, meter-to-charger communication cable; enclosure if needed
Limit to confirm
Meter compatibility and approved household limit

One charger following surplus solar

Equipment to include in the electrician's quote
Same metering equipment, compatible generation setup and feature configuration
Limit to confirm
Installer must confirm inverter export mode and solar behavior

Several chargers plus household sensing

Equipment to include in the electrician's quote
A separately confirmed Dynamic Power Sharing design
Limit to confirm
Wallbox's linked North American network manual is for Pulsar Pro; do not assume a Plus pair plus meter is a complete supported kit
Full comparison table

Swipe to compare. Row labels stay visible.

Desired functionEquipment to include in the electrician's quoteLimit to confirm
Static sharing between Pulsar Plus chargersCompatible chargers, charger-to-charger communication cable and conduit; no household meter requiredShared allowance and local approval for the proposed circuit arrangement
One charger responding to household demandCharger, Wallbox-approved meter and clamps, meter-to-charger communication cable; enclosure if neededMeter compatibility and approved household limit
One charger following surplus solarSame metering equipment, compatible generation setup and feature configurationInstaller must confirm inverter export mode and solar behavior
Several chargers plus household sensingA separately confirmed Dynamic Power Sharing designWallbox's linked North American network manual is for Pulsar Pro; do not assume a Plus pair plus meter is a complete supported kit
Desired functionEquipment to include in the electrician's quoteLimit to confirm
Static sharing between Pulsar Plus chargersCompatible chargers, charger-to-charger communication cable and conduit; no household meter requiredShared allowance and local approval for the proposed circuit arrangement
One charger responding to household demandCharger, Wallbox-approved meter and clamps, meter-to-charger communication cable; enclosure if neededMeter compatibility and approved household limit
One charger following surplus solarSame metering equipment, compatible generation setup and feature configurationInstaller must confirm inverter export mode and solar behavior
Several chargers plus household sensingA separately confirmed Dynamic Power Sharing designWallbox's linked North American network manual is for Pulsar Pro; do not assume a Plus pair plus meter is a complete supported kit

The US EMS installation guide specifies a wired meter connection using STP Class 5E cable. The EMS documentation hub links the separate network designs; the solar guide supplies solar prerequisites.

Accessory: Wallbox US Power Meter kit

Wallbox's current US meter SKU is 000002139. Its kit includes two CT clamps, specified for panels up to 250A; that is a metering limit, not the charger's output. The enclosure is optional and the meter requires a wired connection to the charger. Official kit, meter datasheet, installation requirements.

Solar Charging offers Full-Green, which waits for sufficient surplus, and Eco, which blends surplus and grid energy. Crucially, Wallbox says Solar Charging cannot operate simultaneously with Static Load Management or multi-charger Dynamic Load Management; it can work with single-charger Dynamic Load Management. Schedules and manual charging take priority and may draw grid power. Solar Charging may also discharge a home battery. Solar operating rules.

What works when the internet drops?

An internet outage and a broken charger-to-charger communication link are different faults. The documented behavior is:

Previously configured charging schedule; internet unavailable

Pulsar Plus
Scheduling works without a cloud connection
Home Flex
Saved schedule continues when Wi-Fi drops

Nearby access

Pulsar Plus
App uses Bluetooth; schedule management is documented over Bluetooth
Home Flex
Electrician can configure amperage through Bluetooth without Wi-Fi; activation and connected features require Wi-Fi

Static charger-to-charger sharing; internet unavailable

Pulsar Plus
No internet required
Home Flex
Common-circuit sharing is not supported by the installation FAQ

Secondary charger loses its sharing-network connection

Pulsar Plus
Manual's unpaired-secondary state limits it to 6A; this is not full-speed fallback
Home Flex
Not applicable to a supported sharing installation

Charging-history access

Pulsar Plus
Cloud statistics need internet; nearby Bluetooth synchronization is an alternative
Home Flex
Stored sessions become visible when connectivity returns
Full comparison table

Swipe to compare. Row labels stay visible.

SituationPulsar PlusHome Flex
Previously configured charging schedule; internet unavailableScheduling works without a cloud connectionSaved schedule continues when Wi-Fi drops
Nearby accessApp uses Bluetooth; schedule management is documented over BluetoothElectrician can configure amperage through Bluetooth without Wi-Fi; activation and connected features require Wi-Fi
Static charger-to-charger sharing; internet unavailableNo internet requiredCommon-circuit sharing is not supported by the installation FAQ
Secondary charger loses its sharing-network connectionManual's unpaired-secondary state limits it to 6A; this is not full-speed fallbackNot applicable to a supported sharing installation
Charging-history accessCloud statistics need internet; nearby Bluetooth synchronization is an alternativeStored sessions become visible when connectivity returns
SituationPulsar PlusHome Flex
Previously configured charging schedule; internet unavailableScheduling works without a cloud connectionSaved schedule continues when Wi-Fi drops
Nearby accessApp uses Bluetooth; schedule management is documented over BluetoothElectrician can configure amperage through Bluetooth without Wi-Fi; activation and connected features require Wi-Fi
Static charger-to-charger sharing; internet unavailableNo internet requiredCommon-circuit sharing is not supported by the installation FAQ
Secondary charger loses its sharing-network connectionManual's unpaired-secondary state limits it to 6A; this is not full-speed fallbackNot applicable to a supported sharing installation
Charging-history accessCloud statistics need internet; nearby Bluetooth synchronization is an alternativeStored sessions become visible when connectivity returns

Sources: Wallbox app manual, Wallbox support, sharing manual, ChargePoint settings, installation FAQ, activation requirements. These statements do not guarantee continued household sensing or solar operation after a meter-communication fault.

Cable reach, winter limits and warranty conditions

Plan the cable route to each car's inlet in its normal parking position. The stated lengths above do not establish cold-weather flexibility; we have not compared cable handling.

Wallbox's operating specification is −22°F to 104°F. ChargePoint's datasheet says −22°F to 122°F, but its installation manual revised May 2026 says −40°F to 122°F for North America. Obtain model-specific confirmation before relying on the colder limit. Storage temperatures do not settle this operating conflict. Wallbox specification, ChargePoint datasheet, ChargePoint manual.

Wallbox's main specification table says NEMA Type 4, although its manual's sample label illustration says Type 3R. Home Flex's datasheet specifies Type 3R. Have the installer check the actual unit label and installation suitability rather than relying on the illustration. Wallbox manual, Home Flex datasheet.

Wallbox's limited warranty covers three years, with purchases through Wallbox or authorized sellers and proof of purchase required for service. ChargePoint lists a three-year parts warranty. Its May 2026 manual excludes warranty coverage for installation, commissioning or service outside its certified-technician/approved-method requirements, while its FAQ says any licensed electrician can install. Resolve that conflict with ChargePoint before hiring the installer. Wallbox warranty, ChargePoint manual, FAQ.

  1. Match the equipment

    Confirm the vehicle connector, supply connection and exact hardware model.

  2. Specify the energy feature

    Ask for static sharing, household sensing or solar; quote its complete equipment.

  3. Confirm the installation

    Have the licensed electrician confirm capacity, local requirements, cable reach and warranty conditions.

How we choose

We compare official US specifications, exact shop part codes, installation manuals and feature-activation guides. We favor the simplest documented setup for the household and identify conflicting documents instead of silently choosing a favorable figure. These are research-based recommendations; no charging-speed, winter-cable or app-reliability testing underpins them.

Verdict

Choose Pulsar Plus PUP2 for documented static sharing, or a single Pulsar Plus plus the approved meter for household sensing and solar. Choose Home Flex for one charging point and its home/public app. If you need two chargers, household sensing and solar together, get a model-specific supported design before buying: the documented feature restrictions make that a different purchase from either charger alone.

Frequently asked questions

Is Wallbox Pulsar Plus better than ChargePoint Home Flex?

Choose Pulsar Plus for documented charger-to-charger power sharing, or for single-charger household load management and surplus-solar charging with the extra Wallbox meter. Choose Home Flex when you want home and public charging in the same app. Compare matching installations: both can deliver 40A through their NEMA 14-50 versions, while Home Flex's 50A maximum requires hardwiring.

Can two Wallbox Pulsar Plus chargers share one circuit?

Wallbox documents Power Sharing on a common circuit where local electrical rules allow it. The installation needs compatible chargers, communication cabling, conduit and professional configuration. Its manual says PUP1 and PUP2 cannot share the same Power Sharing network. The shared charging allowance remains a total pool; buying another charger does not create more electrical capacity.

Does Wallbox Pulsar Plus need a power meter?

Ordinary charging and Static Load Management do not require the household power meter. Single-charger Dynamic Load Management and Solar Charging do. Wallbox's US Power Meter includes two clamps; the meter-to-charger communication cable and any needed enclosure must also be accounted for. Have the electrician confirm the complete installation rather than ordering the charger alone for those features.

Will these chargers work without Wi-Fi?

Wallbox documents schedules and Static Load Management without a cloud connection, plus nearby Bluetooth app access. ChargePoint says a saved schedule continues when Wi-Fi disconnects and stored sessions appear after reconnection. That differs from first setup: ChargePoint requires Wi-Fi for activation and connected features, although its installation FAQ permits an electrician to configure amperage through Bluetooth.

Can Wallbox power sharing and solar charging work together?

Wallbox's current Solar Charging guide says it cannot run simultaneously with Static Load Management or multi-charger Dynamic Load Management. It can coexist with single-charger Dynamic Load Management. For solar charging, Full-Green targets surplus generation and Eco mixes surplus with grid electricity. Schedules and manual charging take priority, so a scheduled session can still use grid power.