The runtime calculator

How long will your
power station last?

Pick your appliances, set their on-time, and see the battery capacity and output your plan needs.

Official-source defaultsEvery assumption visible

Wh tells you how long.
W tells you what can run.

We’ll help you check both.
Appliance runtime calculator

01 / Battery size

Your power station

Use the capacity on the spec sheet. Wh is energy; W is output.

Losses & output limits

Example losses from the AC180 manual, §4.4.3. Adjust for your station. A capacity choice does not set its output rating.

Optional: enter the maker’s normal output and surge ratings to check this load. Check surge duration in its manual too.

02 / Build your load

What are you running?

Make a plan

Example hours are editable. Use actual on-time per unit.

Device hours are capped to the plan length. For a fridge or pump, count time actively running.

Wi-Fi router

15 W running 15 W starting

120Wh / plan
Edit wattsOne router or modem. Add each separately.

Starting watts include running watts. Maker’s reference: 10–20 W running; No extra in chart starting. Use your device’s input label or measured draw.

Laptop

65 W running 65 W starting

260Wh / plan
Edit wattsAC charger; draw changes while charging.

Starting watts include running watts. Maker’s reference: 20–100 W (charger) running; No extra in chart starting. Use your device’s input label or measured draw.

LED light

10 W running 10 W starting

80Wh / plan
Edit wattsPer bulb; set the quantity you need.

Starting watts include running watts. Maker’s reference: 8–15 W per bulb running; No extra in chart starting. Use your device’s input label or measured draw.

Add an appliance3 selected

Editable planning values from Champion’s wattage chart, not measurements of your devices.

03 / Your estimate

Estimated runtime

10.6hours

At an average planned draw of 72.5 W, including overhead.

Estimated runtime 10.6 hours. Running load 100 watts. Starting surge 100 watts.

Running load100 W
Starting surge100 W

Running total + the largest single extra starting burst.

Output not fully checked. Enter both ratings above.

Your 8-hour energy plan

Available after losses765 Wh
Plan + overhead580 Wh

Same scale for both bars.

Enough estimated energy for this plan.

Assumes your usage pattern repeats evenly. Device order can change actual runtime. With every selected device on continuously: about 6.7 h on energy alone.

90% usable × 85% inverter · 15 W overhead · no recharging. Source: AC180 example

Find stations for this plan

Filters: at least 1,000 Wh, 100 W continuous and 100 W surge. Uses your chosen size or the larger size this plan needs. Verify the maker’s specifications.

Where the energy goes
Wi-Fi router120 Wh
Laptop260 Wh
LED light80 Wh
Inverter overhead120 Wh
See your estimate~10.6 h

The numbers, explained

A useful estimate. With the working shown.

Allow for losses

We start with 90% usable battery capacity, then 85% inverter efficiency, with 15 W of AC overhead. These are editable examples from the BLUETTI AC180 manual, §4.4.3, not universal power-station specifications. We count overhead throughout the plan.

Use real on-time

Energy is running watts × quantity × hours. A fridge may stay plugged in while its compressor cycles; use actual compressor-on hours. The sample plans are editable examples. Runtime extends your plan’s average draw, assuming the same pattern repeats evenly. It does not model device order.

Leave room to start

Check continuous output against the running total. For one startup at a time, surge is that total plus the largest single (starting − running) burst. If devices can start together, select that option to add every burst, including quantities. A short surge rating must last long enough for the appliance.

Check it by hand

A 1,000 Wh example

  1. Available energy: 1,000 Wh × 0.90 × 0.85 = 765 Wh after capacity and conversion allowances.
  2. An 8-hour plan: 15 W router × 8 h + 65 W laptop × 4 h + 2 × 10 W lights × 4 h = 460 Wh for appliances.
  3. Include overhead: 460 Wh ÷ 8 h + 15 W = 72.5 W average draw in this approximation.
  4. Estimated runtime: 765 Wh ÷ 72.5 W ≈ 10.6 hours. Required nameplate capacity for the 8-hour plan: (460 + 15 × 8) ÷ (0.90 × 0.85) ≈ 759 Wh, rounded up.

AC outlet use only, starting from a full charge, with no solar or other charging during discharge. Temperature, battery age, changing draw, standby behavior and conversion losses can alter runtime. This is an energy-budget approximation, not a runtime guarantee. For cycling loads, use measured energy and the maker’s startup requirements to refine the estimate.

A starting point, not a measurement

Appliance wattage reference

Read the maker’s chart ↗
Editable planning defaults. Starting W is the total during startup, not extra watts.
ApplianceRunningStartingPublished running / starting range
FridgeCount compressor-on time; cycling varies.200 W1,200 W150–400 W
800–1,200 W
CPAP · no heatWithout heated humidification or tubing.60 W60 W30–60 W
No extra in chart
Wi-Fi routerOne router or modem. Add each separately.15 W15 W10–20 W
No extra in chart
LaptopAC charger; draw changes while charging.65 W65 W20–100 W (charger)
No extra in chart
LED lightPer bulb; set the quantity you need.10 W10 W8–15 W per bulb
No extra in chart
TV32–55 inch example; check your label.100 W100 W80–400 W
No extra in chart
Space heaterHigh setting; a large continuous load.1,500 W1,500 W750–1,500 W
No extra in chart
Sump pump⅓ HP example; count actual pumping time.800 W1,600 W500–800 W
1,000–1,600 W
MicrowaveUse electrical input watts from the label.1,200 W1,200 W600–1,200 W
No extra in chart
FanWindow / box fan example.75 W75 W50–200 W
No extra in chart
FreezerCount compressor-on time.200 W1,000 W100–500 W
500–1,000 W
Window AC5,000 BTU example; count compressor-on time.600 W1,200 W450–600 W
900–1,200 W
CPAP · with heatHeated humidifier example; settings matter.120 W120 W60–120 W
No extra in chart
Security systemHome security system example.25 W25 W15–40 W
No extra in chart

Defaults are selected planning values within Champion’s ranges. “No extra in chart” means the reference lists no additional starting load; the default total starting watts equal running watts. Your device may differ. For a microwave, use the electrical requirements in its manual. On small screens, scroll the table to see the source ranges.

Direct from the source

References behind the estimate

Turn your plan into a shortlist.

Start with capacity. Then verify continuous output, surge duration and the connections you need.