The runtime calculator
How long will your
power station last?
Pick your appliances, set their on-time, and see the battery capacity and output your plan needs.
Wh tells you how long.
W tells you what can run.
The numbers, explained
A useful estimate. With the working shown.
Allow for losses
We start with 90% usable battery capacity, then 85% inverter efficiency, with 15 W of AC overhead. These are editable examples from the BLUETTI AC180 manual, §4.4.3, not universal power-station specifications. We count overhead throughout the plan.
Use real on-time
Energy is running watts × quantity × hours. A fridge may stay plugged in while its compressor cycles; use actual compressor-on hours. The sample plans are editable examples. Runtime extends your plan’s average draw, assuming the same pattern repeats evenly. It does not model device order.
Leave room to start
Check continuous output against the running total. For one startup at a time, surge is that total plus the largest single (starting − running) burst. If devices can start together, select that option to add every burst, including quantities. A short surge rating must last long enough for the appliance.
Check it by hand
A 1,000 Wh example
- Available energy: 1,000 Wh × 0.90 × 0.85 = 765 Wh after capacity and conversion allowances.
- An 8-hour plan: 15 W router × 8 h + 65 W laptop × 4 h + 2 × 10 W lights × 4 h = 460 Wh for appliances.
- Include overhead: 460 Wh ÷ 8 h + 15 W = 72.5 W average draw in this approximation.
- Estimated runtime: 765 Wh ÷ 72.5 W ≈ 10.6 hours. Required nameplate capacity for the 8-hour plan: (460 + 15 × 8) ÷ (0.90 × 0.85) ≈ 759 Wh, rounded up.
AC outlet use only, starting from a full charge, with no solar or other charging during discharge. Temperature, battery age, changing draw, standby behavior and conversion losses can alter runtime. This is an energy-budget approximation, not a runtime guarantee. For cycling loads, use measured energy and the maker’s startup requirements to refine the estimate.
A starting point, not a measurement
Appliance wattage reference
| Appliance | Running | Starting | Published running / starting range |
|---|---|---|---|
| FridgeCount compressor-on time; cycling varies. | 200 W | 1,200 W | 150–400 W 800–1,200 W |
| CPAP · no heatWithout heated humidification or tubing. | 60 W | 60 W | 30–60 W No extra in chart |
| Wi-Fi routerOne router or modem. Add each separately. | 15 W | 15 W | 10–20 W No extra in chart |
| LaptopAC charger; draw changes while charging. | 65 W | 65 W | 20–100 W (charger) No extra in chart |
| LED lightPer bulb; set the quantity you need. | 10 W | 10 W | 8–15 W per bulb No extra in chart |
| TV32–55 inch example; check your label. | 100 W | 100 W | 80–400 W No extra in chart |
| Space heaterHigh setting; a large continuous load. | 1,500 W | 1,500 W | 750–1,500 W No extra in chart |
| Sump pump⅓ HP example; count actual pumping time. | 800 W | 1,600 W | 500–800 W 1,000–1,600 W |
| MicrowaveUse electrical input watts from the label. | 1,200 W | 1,200 W | 600–1,200 W No extra in chart |
| FanWindow / box fan example. | 75 W | 75 W | 50–200 W No extra in chart |
| FreezerCount compressor-on time. | 200 W | 1,000 W | 100–500 W 500–1,000 W |
| Window AC5,000 BTU example; count compressor-on time. | 600 W | 1,200 W | 450–600 W 900–1,200 W |
| CPAP · with heatHeated humidifier example; settings matter. | 120 W | 120 W | 60–120 W No extra in chart |
| Security systemHome security system example. | 25 W | 25 W | 15–40 W No extra in chart |
Defaults are selected planning values within Champion’s ranges. “No extra in chart” means the reference lists no additional starting load; the default total starting watts equal running watts. Your device may differ. For a microwave, use the electrical requirements in its manual. On small screens, scroll the table to see the source ranges.
Direct from the source
References behind the estimate
- Champion · appliance wattage chart
Running and starting ranges for each appliance. Our editable starting points sit within these ranges; they are not measurements of your equipment.
- BLUETTI · AC180 manual, §4.4.3 (PDF)
The source of our example 90% usable capacity, 85% inverter efficiency and 15 W overhead. These describe the AC180 example, not every station. The manual also notes the effects of temperature and load.
- Champion · sizing running and starting loads
The maker’s worked sizing examples add the largest starting differential to the running total when devices start separately. Check the duration of your station’s surge rating.
- GE Appliances · microwave electrical requirements
Use the microwave’s electrical requirements in its owner’s manual or installation instructions when checking power needs.
Turn your plan into a shortlist.
Start with capacity. Then verify continuous output, surge duration and the connections you need.