Victron SmartSolar MPPT 75/15 vs 100/30

Which Fits Your System?

Choose the right Victron MPPT for your battery and panels: compare 75/15 and 100/30 limits, cold-weather voltage, lithium settings and monitoring accessories.

By thisWATT EditorialUpdated November 3, 20267 min read

On this page · Quick picks: choose by the requirement that changes

Choose the Victron SmartSolar MPPT 75/15 for a 12V or 24V battery when its 15A charging limit and 220W/440W nominal PV ratings cover your plan. Choose the 100/30 for 30A charging, 440W/880W nominal PV, or a higher PV-voltage allowance, after checking its separate input limits. Neither supports a 48V battery bank.

Quick picks: choose by the requirement that changes

Compare specifications and all conditions

Smaller array; charging demand within the smaller model’s rating

Pick
75/15
Why
220W at 12V or 440W at 24V; 15A battery charging

More charging current or nominal PV capacity

Pick
100/30
Why
440W at 12V or 880W at 24V; 30A battery charging

Physical load-output terminals needed

Pick
75/15, within its load rating
Why
15A physical load output; the 100/30 has virtual load control instead

48V battery or cold array Voc above 100V

Pick
Neither
Why
Revisit the controller or array design
Full comparison table

Swipe to compare. Row labels stay visible.

Your requirementPickWhy
Smaller array; charging demand within the smaller model’s rating75/15220W at 12V or 440W at 24V; 15A battery charging
More charging current or nominal PV capacity100/30440W at 12V or 880W at 24V; 30A battery charging
Physical load-output terminals needed75/15, within its load rating15A physical load output; the 100/30 has virtual load control instead
48V battery or cold array Voc above 100VNeitherRevisit the controller or array design
Your requirementPickWhy
Smaller array; charging demand within the smaller model’s rating75/15220W at 12V or 440W at 24V; 15A battery charging
More charging current or nominal PV capacity100/30440W at 12V or 880W at 24V; 30A battery charging
Physical load-output terminals needed75/15, within its load rating15A physical load output; the 100/30 has virtual load control instead
48V battery or cold array Voc above 100VNeitherRevisit the controller or array design

The model name describes maximum PV voltage / maximum battery charge current. The 30A in 100/30 is battery-side charging current; its separate maximum PV short-circuit current is 35A. Use the general solar charge controller guide for MPPT-versus-PWM background; this comparison is about choosing between these exact SmartSolar models.

  • 15A75/15 maximum battery charge current
  • 30A100/30 maximum battery charge current

Published limits and your requirements worksheet

These figures come from Victron’s model-specific 75/15 table and 100/30 table. Record the proposed system in the last column before ordering.

Battery voltage

SmartSolar 75/15
12V or 24V
SmartSolar 100/30
12V or 24V
Your planned system
Battery-bank voltage: ___

Battery charge current

SmartSolar 75/15
15A maximum
SmartSolar 100/30
30A rated
Your planned system
Battery maker’s allowed current: ___

Nominal PV at 12V battery voltage

SmartSolar 75/15
220W
SmartSolar 100/30
440W
Your planned system
Array nameplate watts: ___

Nominal PV at 24V battery voltage

SmartSolar 75/15
440W
SmartSolar 100/30
880W
Your planned system
Use the row for your battery

Maximum PV open-circuit voltage (Voc)

SmartSolar 75/15
75V
SmartSolar 100/30
100V
Your planned system
Cold-corrected array Voc: ___

Maximum PV short-circuit current (Isc)

SmartSolar 75/15
15A
SmartSolar 100/30
35A
Your planned system
Array design Isc: ___

PV startup / running requirement

SmartSolar 75/15
Above battery voltage by 5V / 1V
SmartSolar 100/30
Above battery voltage by 5V / 1V
Your planned system
Hot-weather operating voltage: ___

Physical load output

SmartSolar 75/15
15A continuous
SmartSolar 100/30
None; virtual control available
Your planned system
Load-output requirement: ___

Local communication

SmartSolar 75/15
Built-in Bluetooth; VE.Direct
SmartSolar 100/30
Built-in Bluetooth; VE.Direct
Your planned system
Phone, display or remote access: ___
Full comparison table

Swipe to compare. Row labels stay visible.

RequirementSmartSolar 75/15SmartSolar 100/30Your planned system
Battery voltage12V or 24V12V or 24VBattery-bank voltage: ___
Battery charge current15A maximum30A ratedBattery maker’s allowed current: ___
Nominal PV at 12V battery voltage220W440WArray nameplate watts: ___
Nominal PV at 24V battery voltage440W880WUse the row for your battery
Maximum PV open-circuit voltage (Voc)75V100VCold-corrected array Voc: ___
Maximum PV short-circuit current (Isc)15A35AArray design Isc: ___
PV startup / running requirementAbove battery voltage by 5V / 1VAbove battery voltage by 5V / 1VHot-weather operating voltage: ___
Physical load output15A continuousNone; virtual control availableLoad-output requirement: ___
Local communicationBuilt-in Bluetooth; VE.DirectBuilt-in Bluetooth; VE.DirectPhone, display or remote access: ___
RequirementSmartSolar 75/15SmartSolar 100/30Your planned system
Battery voltage12V or 24V12V or 24VBattery-bank voltage: ___
Battery charge current15A maximum30A ratedBattery maker’s allowed current: ___
Nominal PV at 12V battery voltage220W440WArray nameplate watts: ___
Nominal PV at 24V battery voltage440W880WUse the row for your battery
Maximum PV open-circuit voltage (Voc)75V100VCold-corrected array Voc: ___
Maximum PV short-circuit current (Isc)15A35AArray design Isc: ___
PV startup / running requirementAbove battery voltage by 5V / 1VAbove battery voltage by 5V / 1VHot-weather operating voltage: ___
Physical load output15A continuousNone; virtual control availableLoad-output requirement: ___
Local communicationBuilt-in Bluetooth; VE.DirectBuilt-in Bluetooth; VE.DirectPhone, display or remote access: ___

The PV wattage entries are nominal sizing ratings, not guaranteed charging output. Both controllers limit input power when more PV wattage is connected, but that does not relax the voltage or Isc limits. Both are fully rated up to 40°C ambient; output is reduced above that temperature.

Choose the 75/15 for an array that already fits

The 75/15 is our smaller-system pick when its battery-current, nominal-wattage and PV input limits all fit, including planned expansion. It also preserves a physical load output with configurable low-voltage disconnection, useful when the system needs that function. That output is limited to 15A; a high-current inverter can exceed its capacity.

You retain built-in Bluetooth, VictronConnect settings and firmware updates, plus the VE.Direct port. We would keep the smaller controller when the requirements fit and the larger model would add unused charging capacity.

View the SmartSolar 75/15 on Victron’s site

Choose the 100/30 when a documented limit requires it

The 100/30 is our pick for greater charging capacity: its nominal PV rating and battery-current allowance are double the 75/15’s at the same battery voltage. It also raises the PV Voc ceiling from 75V to 100V and the Isc allowance from 15A to 35A. Those are independent reasons to upgrade; needing more voltage headroom does not necessarily mean needing more charging current.

The tradeoff is the absence of physical load-output terminals; virtual control needs the corresponding external equipment. Its maximum charge-current setting can be reduced for a battery that needs less current. Do not assume that a battery can accept the controller’s full output: have its maker’s charging limits checked against the selected setting.

View the SmartSolar 100/30 on Victron’s site

Look-alikes and conflicting family-page wording

SmartSolar and BlueSolar are different versions: SmartSolar has built-in Bluetooth; BlueSolar needs an optional dongle for Bluetooth. The SmartSolar 100/15 is another possible specification match when only the voltage ceiling needs to rise: it retains 15A charging and 220W/440W nominal PV ratings, with a 100V PV ceiling. The 100/50 is also a different controller, rated for 50A charging; do not read its adjacent specification column as the 100/30’s.

Victron’s small-controller family page says “12/24/48 Volt,” while the exact 75/15 table specifies 12V or 24V. The family marketing also mentions a VE.Can connection; the exact manuals for these picks specify VE.Direct. Use the model-specific limits and ports when buying accessories.

Check panel watts, cold voltage and current separately

Start with the battery-voltage row: the same 440W nominal array matches the 75/15’s 24V rating or the 100/30’s 12V rating. Moving to the larger controller can avoid power limiting, but cannot make an incompatible battery voltage work.

For the panel worksheet, collect the exact model, rated power, Voc, maximum-power voltage (Vmp), Isc and Voc temperature coefficient from its datasheet. Ask the system designer to check the proposed array arrangement and lowest design temperature, including future panels. Victron warns that Voc rises below 25°C and that the panel’s temperature coefficient must be included. Also check the lower PV operating requirement in hot weather; passing the cold-voltage ceiling alone does not establish a complete match.

Compare array short-circuit current, rather than panel operating current, with the Isc row. Victron’s datasheet warns that excess array Isc can damage the controller. Victron’s manual qualifies that warning by specifying reverse-polarity connection of the PV array. Have the designer apply the panel manual’s design factors and site requirements; the examples below use nameplate Isc only.

Worked examples: a smaller pick, an upgrade and neither

Use an identifiable panel as the starting point: Victron’s BlueSolar datasheet lists the SPM041501200 at 150W, Vmp 18.2V, Voc 22.3V and Isc 8.69A. Its Voc temperature coefficient is −0.35%/°C, and the STC reference temperature is 25°C. These are calculations for proposed arrays of identical panels, assuming a minimum panel temperature of −10°C; they are not measured output or a local climate recommendation.

For these panels below the reference temperature, calculate cold array Voc = panel count × 22.3V × [1 + (0.35 ÷ 100) × (25 − minimum panel temperature in °C)]. The proposed series strings below assume identical panels: their Voc values add, while each string’s nameplate Isc remains 8.69A. For four panels at the assumed minimum, 4 × 22.3V × [1 + (0.35 ÷ 100) × (25 + 10)] exceeds 100V, ruling out both controllers.

Single 150W panel; 12V battery

Cold-voltage result at −10°C
Below 75V
Selection
75/15 candidate: within 220W nominal PV and 15A Isc

Two 150W panels in a series string; 12V battery

Cold-voltage result at −10°C
Below 75V
Selection
100/30 preferred: 300W is within 440W nominal PV; 75/15 would be oversized and could limit power

Four 150W panels in a series string; 24V battery

Cold-voltage result at −10°C
Just above 100V
Selection
Neither: 600W fits the 100/30’s 880W nominal rating, but cold Voc fails
Full comparison table

Swipe to compare. Row labels stay visible.

Proposed array and batteryCold-voltage result at −10°CSelection
Single 150W panel; 12V batteryBelow 75V75/15 candidate: within 220W nominal PV and 15A Isc
Two 150W panels in a series string; 12V batteryBelow 75V100/30 preferred: 300W is within 440W nominal PV; 75/15 would be oversized and could limit power
Four 150W panels in a series string; 24V batteryJust above 100VNeither: 600W fits the 100/30’s 880W nominal rating, but cold Voc fails
Proposed array and batteryCold-voltage result at −10°CSelection
Single 150W panel; 12V batteryBelow 75V75/15 candidate: within 220W nominal PV and 15A Isc
Two 150W panels in a series string; 12V batteryBelow 75V100/30 preferred: 300W is within 440W nominal PV; 75/15 would be oversized and could limit power
Four 150W panels in a series string; 24V batteryJust above 100VNeither: 600W fits the 100/30’s 880W nominal rating, but cold Voc fails

The candidate picks still require battery-profile approval and a check of startup and hot-weather operating voltage. Use Victron’s MPPT calculator with your actual panel data and have the proposed design reviewed before ordering.

Battery profiles and winter lithium charging

Victron lists lithium, AGM, gel and flooded compatibility, and both manuals describe adjustable charge algorithms and current limits. Match the battery maker’s charge-voltage, current and temperature requirements; the lithium preset does not support equalization.

Cold-charge protection needs a separate check. The 75/15 and 100/30 settings manuals say low-temperature cutoff is disabled by default and works only when a VE.Smart network supplies a battery-temperature reading from compatible external sensing hardware. The internal controller sensor alone does not satisfy that requirement. For battery selection, continue to our winter RV lithium battery guide.

Monitoring and the accessories to account for

The 75/15 and 100/30 manuals document local Bluetooth monitoring, configuration and firmware updates through VictronConnect. Their manuals list an optional VE.Direct-to-USB interface for USB access, and optional GX or GlobalLink 520 hardware for internet/LAN access through VRM. The optional MPPT Control display uses VE.Direct; its required VE.Direct cable is not included with that display.

For external battery-temperature and voltage sensing, the manuals document Smart Battery Sense, or a compatible BMV-712 Smart/SmartShunt monitor equipped with the appropriate temperature sensor. Choose accessories for the required function, rather than assuming that Bluetooth includes a display, internet access or battery-temperature measurement.

  • Yes: Local phone monitoring: built-in Bluetooth
  • Partly: Fixed display: optional MPPT Control and a separate VE.Direct cable
  • Partly: Internet monitoring: optional GX or GlobalLink communication hardware

How we choose

We compared official Victron product pages, exact-model specification tables, manuals and panel data. The recommendations are research judgments, without physical product testing; array examples are stated calculations with explicit temperature assumptions. A qualified installer should validate the electrical design and handle installation.

Verdict

Choose the 75/15 when the complete array and battery requirements fit its limits, especially if a physical load output matters. Choose the 100/30 when its extra charging capacity or PV headroom solves a documented requirement. For a 48V battery or an array that exceeds the larger model’s cold-voltage ceiling, choose neither and revisit the design.

Frequently asked questions

What do 75/15 and 100/30 mean on a Victron MPPT?

The first number is the maximum PV open-circuit voltage; the second is maximum battery charging current. The 75/15 therefore has a 75V PV ceiling and 15A battery-current limit, while the 100/30 has a 100V ceiling and 30A charging limit. Neither number specifies battery-bank voltage or panel wattage; check those separately.

Can a Victron SmartSolar 75/15 handle 400W of solar?

At 24V battery voltage, 400W is within its 440W nominal PV rating. At 12V it exceeds the 220W nominal rating, so it is an oversized array and the controller can limit input power. In either case, cold-corrected Voc must fit the 75V ceiling and array short-circuit current must fit 15A. Get the proposed array checked before buying.

Do these SmartSolar controllers need a Bluetooth dongle?

Both have built-in Bluetooth for local VictronConnect access, so a separate dongle is unnecessary for that job. BlueSolar is a different family without built-in Bluetooth. Internet monitoring is also a separate requirement: the SmartSolar manuals specify optional GX or GlobalLink hardware for VRM access. Built-in Bluetooth alone does not provide remote internet monitoring.

Will the SmartSolar 100/30 charge a 48V battery?

No. The model-specific specification tables limit both the 100/30 and 75/15 to 12V or 24V batteries. The 100 in 100/30 describes the PV voltage ceiling, not support for a 48V battery. Choose a controller whose own model table explicitly supports your battery-bank voltage, rather than relying on a family-page heading.

Can either controller charge LiFePO4 batteries in winter?

Both offer adjustable charging, but the battery maker must approve the profile, charging current and temperature limits. Their low-temperature cutoff is disabled by default and operates only when a VE.Smart network supplies an external battery-temperature reading. Verify the battery’s own cold-charge protection and the controller’s configuration; an internal controller-temperature sensor alone does not establish that protection.